DC Chemicals · Product datasheet

Zuranolone — Datasheet

CAT. NO. DC72829

Product page and current package options

ParameterValue
Chemical NameZuranolone
CAS No.1632051-40-1
SynonymsSAGE-217;Zuranolone;7ZW49N180B;Zuranolone [INN];Zuranolone [USAN];Zuranolone (USAN/INN);AMY27908;BDBM50258216;WHO 10896;DB15490;D11793
FormulaC25H35N3O2
M.Wt409.564306497574
SMILESC[C@]12[C@]([H])([C@]3([C@@]([H])([C@@]4([C@]([H])(CC3)C[C@](CC4)(C)O)[H])CC2)[H])CC[C@@H]1C(CN5C=C(C#N)C=N5)=O
Purity>98%
Storage2 years -20°C Powder, 2 weeks 4°C in DMSO, 6 months -80°C in DMSO

Biological Activity

Zuranolone(SAGE-217, CS-2797) is an orally active and potent neuroactive steroid and positive allosteric modulator of the GABAA receptor, with EC50s of 296 nM for α1β2γ2 receptor.

In Vitro

Kinase assay demonstrates that SAGE-217 is a potent GABAA receptor agonist with EC50s of 296 and 163 nM for α1β2γ2 and α4β3δ GABAA receptors, respectively. SAGE-217 is currently being studied in parallel phase 2 clinical trials for the treatment of postpartum depression (PPD) and major depressive disorder (MDD). SAGE-217 shows >30 μM inhibition in a cardiac panel of eight relevant cardiac ion channels. At 10 μM concentration of SAGE-217, only binding at the glycine (57%), sigma receptors (88%), and inhibition of the transient receptor potential vanilloid 1 (TRPV1, 95%) is noted[1].

In Vivo

Acute administration of SAGE-217 (0.3 to 10 mg/kg, ip) effectively reduces pentylenetretazol (PTZ)-induced seizures in mice (MECplasma=85 nM) as well as produces a dose-dependent anticonvulsant effect in the mouse 6 Hz electrical stimulation model. In the rat lithium-pilocarpine model of status epilepticus (SE), SAGE-217 (0.3 to 5 mg, iv) abolishes both behavioral and electrographic seizure activity, even when administered 60 min after induction of SE. Additional PK studies of SAGE-217 in dog show low clearance (<10% of hepatic blood flow), resulting in excellent oral bioavailability (F=68%)[1].

Target

EC50: 296 nM (α1β2γ2 GABAA receptor), 163 nM (α4β3δ GABAA receptor)[1]

Kinase Assay

Cortices are rapidly removed following decapitation of euthanization by carbon dioxideasphyxiation Sprague-Dawley rats (200 to 250 g). The cortices are homogenized in 10 volumes of ice-cold 0.32 M sucrose using a glass/teflon homogenizer and centrifuged at 1500× g for 10 min at 4°C. Aliquots (100 μL) of the membrane suspensions are incubated with 3 nM [35S]-TBPS and 5 μL aliquots of SAGE-217 dissolved in DMSO (final 0.5%) in the presence of 5 μM GABA. The incubation is brought to a final volume of 1.0 mL with buffer. Following a 90 min incubation at room temp, the assays are terminated by filtration through glass fiber filters using a cell harvester and rinsed three times with ice-cold buffer. Filter bound radioactivity is measured by liquid scintillation spectrometry[1].

Animal Administration

In vivo pharmacokinetic parameters are determined in male Sprague Dawley rats (of 200 to 300 g in weight), male CD-1 mice (15 to 25 g in weight), and male beagle dogs (8 to 12 kg in weight). Doses of SAGE-217 for intravenous (IV) and oral administration (PO) are formulated as solutions in SBECD. SAGE-217 is dosed IV (5 mg/kg, 2.5 mL/kg) or by oral gavage (20 mg/kg, 10 mL/kg). Animals in the IV group are sampled at 0.083, 0.25, 1, 2, 4, and 8 hours post-dose and PO animals are sampled at 0.5, 1, 2, 4, and 8 hours post dose. Brain samples from the IV group are also collected at 1 hour post-dose. Blood samples are collected into tubes treated with K2-EDTA, then centrifuged at 2000 g at 4°C for 15 min. Plasma is isolated and frozen at -70°C until extraction[1].

References & source

[1]. Martinez Botella G, et al. Neuroactive Steroids. 2. 3α-Hydroxy-3β-methyl-21-(4-cyano-1H-pyrazol-1'-yl)-19-nor-5β-pregnan-20-one (SAGE-217): A Clinical Next Generation Neuroactive Steroid Positive Allosteric Modulator of the (γ-Aminobutyric Acid)A Receptor. J Med Chem. 2017 Sep 28;60(18):7810-7819.

DC Chemicals original product information

Published experimental findings depend on the model and assay conditions. They do not guarantee equivalent performance in every application. For laboratory research use only.

Cart

Request quotation