Instructions for Use

Before use

Check the supplied lot number, batch COA, approved SDS, quantity and retest date. Pure form: −20 °C, 1 year; In solvent: −80 °C, 6 months; −20 °C, 1 month. Sealed and protected from light.

For small quantities of viscous or oily lipid, volumetric transfer can reduce weighing losses. Confirm solvent compatibility and solubility before preparing a stock; calculated volumes do not establish solubility.

Stock-solution planning

Volume (mL) = mass (mg) × 1000 / [molecular weight × concentration (mM)].

Mass10 mM20 mM
10 mg1.6834 mL0.8417 mL
25 mg4.2084 mL2.1042 mL
50 mg8.4168 mL4.2084 mL
100 mg16.8336 mL8.4168 mL

Literature formulation reference

ComponentDC Chemicals productMolecular weightMolar ratioMass at 1 µmol total lipid (mg)
GVS-18-B6DC60564594.0554.6Not calculable from disclosed data
DSPCDC57005790.1510.9Not calculable from disclosed data
CholesterolDCD-041386.6532.8Not calculable from disclosed data
mPEG-DMANot uniquely mappedNot established1.6Not calculable from disclosed data

The nominal ratio is from Materials and Methods, LNP Production, in the order GVS-18-B6:DSPC:cholesterol:PEG lipid. Its rounded total is 99.9. SI Table S2 identifies mPEG-DMA and separately reports pre- and post-formulation measurements. PEG molecular weight and exact catalog mapping remain unassigned, so a complete mass conversion is not prefilled. The low-PEG hemolysis formulation is a separate experiment. No N/P value is inferred.

Read the complete study conditions, biological results, tolerability and figures →

References

  1. Holland R, Lam K, Jeng S, et al. Silicon Ether Ionizable Lipids Enable Potent mRNA Lipid Nanoparticles with Rapid Tissue Clearance. ACS Nano. 2024;18:10374–10387. DOI: 10.1021/acsnano.3c09028. Table 1; Figures 2–7; Materials and Methods.
  2. Supporting Information, nn3c09028_si_001.pdf. Table S2 (mPEG-DMA and measured composition); Figure S3 (hemolysis); Figure S4 (protein corona).