← Acuitas Lipid series · DCL0038
Acuitas Lipid series · selection and comparison
Selected from the single additional Example 3 screen: PR8 HA mRNA, 0.2 µg per injection, intramuscular BALB/c mice, n=10/group, prime day 0/boost day 14, HAI endpoint day 28. Ranking uses the reported means; no statistical superiority is asserted.
| Descriptive rank | Catalog | Product | Mean HAI | HAI / I-1 (calculated) | Reported pKa | Calculated MW |
|---|---|---|---|---|---|---|
| 1 | DCL0043 | Acuitas Lipid I-19 | 1888 | 4.63 | 6.58 | 958.68 |
| 2 | DCL0042 | Acuitas Lipid I-15 | 1784 | 4.37 | 6.70 | 1032.76 |
| 3 | DCL0044 | Acuitas Lipid I-23 | 1760 | 4.31 | 6.34 | 1032.76 |
| 4 | DCL0039 | Acuitas Lipid I-9 | 1665 | 4.08 | 6.91 | 795.33 |
| 5 | DCL0045 | Acuitas Lipid I-24 | 1664 | 4.08 | 6.74 | 1072.78 |
| 6 | DCL0046 | Acuitas Lipid I-25 | 1632 | 4.00 | 6.54 | 946.67 |
| 7 | DCL0047 | Acuitas Lipid I-26 | 1368 | 3.35 | 6.44 | 682.13 |
| 8 | DCL0038 | Acuitas Lipid I-4 | 1337 | 3.28 | 6.64 | 948.60 |
| 9 | DCL0041 | Acuitas Lipid I-13 | 1296 | 3.18 | 6.83 | 874.57 |
| 10 | DCL0040 | Acuitas Lipid I-12 | 1288 | 3.16 | 6.78 | 819.23 |
I-1 mean HAI is 408 in this screen. I-12 and I-27 tie at 1288 for the tenth position. I-12 is included by lower patent compound number; I-27 is a tied reserve and has not been shown inferior.
The series is classified for intramuscular vaccine research. HA antibody responses do not establish direct muscle-fiber transfection, cancer-vaccine efficacy or an intravenous organ-targeting claim.
Example 3 screening table, printed p.67 / PDF p.68 · Original source PDF · Structure/data CSV · Structures (SDF)